Installation And Connection; Installing The Magnetically Coded Position Measuring System - Balluff BML-S1G0-7-M5E-0 Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BML-S1G0-_7_ _-M5E_-_0-_ _
Absolute Magnetically Coded Position Measuring System
4

Installation and connection

4.1
Installing the magnetically coded position
measuring system
During assembly, make sure that the sensor head is
correctly positioned over the magnetic tape. The distances
and tolerances must be complied with to ensure the
correct function and linearity class of the system specific to
the application.
DANGER
Uncontrolled system movement
If the sensor head or tape move from their position, an
abrupt change in the output signals may take place
associated with immediate and unexpected system
movements. Persons located in the tilt or travel area may
be severely injured.
► Ensure that the sensor head and tape are firmly
attached over the entire service life under the actual
ambient conditions.
► In safety applications ensure proper fastening
implementation and measures for preventing errors,
e.g. by performing an FMEA (Failure Mode and
Effects Analysis).
► Notify installation and service personnel accordingly.
NOTICE
Interference in function
Improper assembly of the magnetic tape and sensor
head may impair function of the linear encoder system
and lead to increased wear or damage to the system.
► All permissible distance and angle tolerances (see
section 4.1.1) must be strictly complied with.
► The sensor head may not come into contact with
the magnetic tape over the entire measuring range.
Contact must also be avoided if the magnetic tape is
covered by a cover strip (optional).
► The linear encoder system must be installed in
accordance with the indicated degree of protection.
External magnetic fields change the functional properties.
Magnetic fields with ≥ 1 mT reduce the precision of the
system, magnetic fields of ≥ 30 mT destroy the magnetic
tape. The functionality of the system is no longer
ensured.
► Direct contact with magnetic clamps or other
permanent magnets must be avoided.
No forces may be exerted on the plug on the housing.
► Provide the cable with a strain relief.
www.balluff.com
Note:
Orient sensor head and tape so that the arrow
on the sensor head part label (see Fig. 12-1 on
page 33) points in the same direction as the
arrow on the tape (see Fig. 3-2 on page 8).
english
9

Publicidad

Tabla de contenido
loading

Tabla de contenido