H A N D L I N G T H E C O O L A N T / L U B R I C A N T ( C / L )
8.2
Removing the C/L Container
For table version:
▷ Remove the C/L drain pipe [1] on the side of the
Ceramill Coolstream.
Fig. 24
1 C/L drain pipe
NOTE:
Possible damage of the electric lines and the C/L
supply line:
▷ When moving the Ceramill Coolstream, pay
attention that no lines are driven over.
▷ Move the Ceramill Coolstream out of the table.
For both versions:
▷ Remove the left sidewall of the Ceramill Cool-
stream.
▷ Pull the C/L drain pipe [1] and the C/L supply line
[3] from above out of the C/L container.
▷ Disconnect the control cable [2] at the partition
wall (between the chamber for the Ceramill Air-
stream and the container).
1
Fig. 25 Disconnecting the interfaces of the C/L
container (tower version)
Fig. 26 Disconnecting the interfaces of the C/L
container (table version)
Legend to Fig. 25 and Fig. 26:
1 C/L drain pipe
2 Control cable
3 C/L supply line
1
2
3
2
3
E N
1
77