H A N D L I N G T H E C O O L A N T / L U B R I C A N T ( C / L )
▷ Open the drain cock.
The C/L in the C/L container drains into the dis-
posal receptacle.
When the C/L container is empty:
▷ Shut the drain cock again.
Dispose of the C/L in accordance with the
applicable regulations and laws. Proper
disposal of the C/L must be documented.
8.4
Cleaning the C/L Container
NOTE:
The filter and the C/L container may only be
cleaned with water.
▷ Do not use cleaning agents.
▷ Unscrew and remove the four star-knob nuts on
the top side of the C/L container.
▷ Remove the cover with the drain pipe.
▷ Remove the filter bag and empty it.
▷ Clean the filter bag.
▷ Rinse and clean the C/L container.
8.5
Filling in C/L
The water for the coolant/lubricant must
have drinking-water quality. The optimal
hardness range is between 10 - 20 °dH
(corresponds to 1.8 - 3.6 mmol total hard-
ness per litre). When the hardness is far
beyond this range, we recommend the
addition of distilled water.
▷ Fill 20 litres of water and 1 litre of Ceramill Cool-
ant into a separate container and mix well.
▷ Insert the filter bag into the C/L container.
▷ Pour the mixed C/L into the C/L container.
▷ Reattach the cover with the drain pipe and
secure it with the four star-knob nuts.
E N
79