⑭ Power indicator (POWER)
The LED indicator stays on in green while the camera power is on. This camera
does not have own power on/off switch. Utmost care should be paid when
doing repair or service work. The maintenance indicator is built-in which makes
blinking Amber and Green lights around 40,000 hours operation. It is strongly
recommended to have a proper maintenance service if this maintenance
indication LED blinks.
⑮ Terminal switch for GEN-LOCK
This is to terminate GEN-LOCK signal with 75 ohms impedance when the loop
connection is made in Gen-lock signal feed. To terminate, make this switch ON.
⑯ Terminal switch for RS-485
In RS-485 communication link , turn this switch to ON side for one-to-one control,
or turn it to OFF side for daisy-chain(loop connection).
(For use in daisy-chain connection, turn ON the terminal switch of the last device
in the link.)
⑰ RS-485 input/output vs. Day/Night change-over terminal block
This block is used for RS-485 connection or for remote control of day/nigh
switching.
⑱ DC12V/AC24V power input terminal
For power, apply the input power of DC10.5 - 28.0 V or AC24V ±10%.
* This installation should be made by a qualified service person and should
conform to all local codes.
⑲ AC 100V power cable (In NTSC, Japanese version Only)
For AC 100V power supply.
Applicable AC should be within a range of plus/minus 10% voltage.
Note: This camera has no power switch.
Just plug in the power cable and the camera power turns ON. To make the
camera power off, just unplug a power cable.
The power outlet should be handy near the camera and should be easily
accessible.