Ikegami ICD-809 Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

① Lens mount (CS mount)
This is used to mount the lens on the camera. Many types of CS mount lens
can be used.
② Lens flange back focus adjuster
To be used to adjust the lens flange back focal distance (distance between lens
mounting edge and image focal point), if the camera fails to come into focus
with the lens' focus ring, this can be used for re-adjustment of lens back focus
when replacing lens.
③ Back focus lock screw
To be used to fix the lens flange back after it has been adjusted.
④ Camera mounting screw holes
These holes are used to install and fix the camera on the camera mounting or
bracket. Those can be also applicable to normal use tripods which have a quarter
inch thread. This mount, with two mounting holes, can be re-positioned on either
the bottom or the top of the camera as required.
Note:
To use these holes to attach the camera on a tripod or other mount, make
sure you use suitable size mounting bolts as follows (1/4" -20UNC), they
should not be longer than 5.5 mm to avoid an un-stable installation.
⑤ Lens iris control selector switch
The switch has two positions, for a video controlled auto-iris lens or a DC auto-
iris lens.
⑥ Auto iris lens connector:
Specifically used to connect the auto iris lens.
• For the video controlled type auto iris lens
Set the lens selector switch to VIDEO position.
– Connector cable leads –
1. Red (power)
2. Not used
3. White (video)
4. Black (shielded)
* Make proper isolation on the tip of the green wire to prevent a short-circuit.
4
2
3
1
E-6
Auto iris lens