5-4-8. MENU LOCK
To prevent un-intentional or intentional setup parameter change, this Menu Lock
function is provided for protection. The menu lock function protects saved setting
parameters against accidental or intentional alteration.
(1) To Lock
To secure the saved setting parameters to make it ON, using E button.
(2) Operation
When locked, Only EXIT is effective and all the other actions are invalid.
(3) Unlock
To un-lock, press the U, R, D, L, U, D and E buttons in this order.
If a wrong button is pressed halfway, start all over again.
5-4-9. SPECIAL MENU
(1) To go to the Special Menu, push L and
R buttons together at the SET UP
position.
The SPECIAL MENU screen shows up,
as shown on right.
(2) CHROMA
With the L and R buttons, the chroma
level can be adjusted. Make the
adjustment to your desired level while
watching a monitor screen.
(3) DETAIL
With the L and R buttons, the detail level can be adjusted. Make the adjustment
to your desired level while watching a monitor screen.
(4) PEDESTAL
By L and R buttons, the pedestal level can be adjusted. Make this adjustment
to your desired level while watching a monitor screen.
(5) VIDEO LEVEL
With the L and R butons, the video level can be adjusted.
Make the adjustment to your desired level while watching a monitor screen.
(6) GAMMA
With the L and R buttons, the gamma correction can be selected (0.45/0.75/
1.0).
   SPECIAL MENU  V3.00
 PAGE        1/2
 CHROMA      L・・・・I・・・H
 DETAIL      L・・・・I・・・H
 PEDESTAL    L・・・・I・・・H
 VIDEO LEVEL L・・・・I・・・H
 GAMMA       0.45
 MATRIX      A MODE
 MONITOR     CRT
      RET   EXIT
E-20