ELECTRONIC CIRCUIT BOARD

ACS
request
sensor
Antenna
(Ottawa/Atlanta)
RS232
socket
Boiler pump
Note: A code 651270 connection
cable kit and a code 648690 boiler
temperature detection sensor are
necessary to connect the boiler
pump.
The pellet thermo-stoves are equipped with the LEONARDO® SYSTEM, which provides for optimal combustion.
LEONARDO® ensures excellent operation thanks to two sensors measuring the pressure level in the combustion chamber and
smoke temperature. The detection of and subsequent optimisation of these two parameters is continuous in order to correct opera-
tion anomalies in real time.
The LEONARDO® system offers constant combustion, automatically regulating the draft based on the characteristics of the chim-
ney flue (bends, length, shape, diameter, etc..) and environmental conditions (wind, humidity, atmospheric pressure, installations at
high altitude, etc.). The standards for installation must be respected.
LEONARDO ® system is also able to recognise the type of pellets and automatically adjust the flow moment by moment to ensure
the required level of combustion (use wood pellets with a diameter of approximately 6 mm).
FEATURES
CONSOLLE cod. 612600
RPM Screw 1
ACS-IN
RPM smoke
Panel control
RS232
Vacuum gauge
Tx/sx radio module
(Ottawa)
Li t hi um
backup battery
+
C R2032
Smoke expulsion
motor
Screw 1
Screw 2
Outlet pump
31
Archimedes'
screw 2 probe
RPM Screw 2
Thermocouple
Water outlet probe
Vacuum gauge
P2
P1
EV ACS
Reading points
230 Vac Power
50Hz +/-10%
2A Fuse
Stove rear socket
Control board
Vacuum gauge
Smoke sensor