1) What do I need to prepare in order to install the thermal stoves?
Smoke outlet that is at least 100 mm in diameter.
An air inlet in the room that is at least 80 cm².
¾" G outlet and inlet fitting.
¾" G drains connection for overpressure valve.
¾" G load fitting.
A certified electrical connection with a thermal magnetothermic switch 230V +/- 10% 50 Hz.
(assess the division of primary and secondary circuits).
2) Can the thermo-stoves work without water?
NO. Using the thermo-stoves without water will damage it.
3) Do thermal stoves emit hot air?
NO. Most of the heat is transferred to the water.
Only Quebec / Toronto / Montreal / Detroit / Boston / Miami emit a small amount in the installation environment in the form of radia-
tion from the glass hearth. It is advisable in any case to use a radiator in the same room.
4) Can I connect the inlet and outlet of the thermo-stoves directly to a radiator?
NO, just like other boilers, it must be connected to a collector from which the water is then distributed to the radiators.
5) Do thermal stoves also supply hot sanitary water?
It is possible to produce domestic hot water using the KIT built in to the stove, this is an instantaneous production without accumula-
tion.
6) Can I discharge the smoke from the thermal stoves along the wall?
NO, a discharge which is conform with standards (UNI 10683/05) must reach the ridge of the roof, and in any case proper functioning
requires a vertical stroke of at least 1.5 meters; avoiding that in case of power outage or wind, a slight amount of smoke forms in the
installation environment.
7) Do I need an air inlet in the room where it is installed?
Yes, to replenish the air used by the thermo-stoves for combustion. The smoke extractor draws the air from the room into the combu-
stion chamber.
8) What settings are required on the thermo-stoves display?
The desired water temperature. The thermo-stoves will then adjust the power accordingly to obtain or maintain this.
For small systems, a mode can be set that ignites and shuts down the thermo-stoves accordingly, as the water temperature is reached.
(contact DEALER for initial start up)
9) Do I need to vacuum the pellet hopper?
Yes, at least once a month when the thermo-stoves is not used for some time.
10) Can I burn other fuel apart from pellets?
NO. The thermo-stoves has been designed to burn wood pellets that are 6 mm in diameter. Any other material can damage it.
11) Can I ignite the thermo-stoves by sending an SMS?
Yes, if the DEALER or an electrician has installed the connection via an optional cable code 640560 to the serial port behind the ther-
mo-stoves

CLEANING ACCESSORIES (optional extras)

GlassKamin
(code 155240)
Used for cleaning the
ceramic glass
FAQ
53
Ash vacuum cleaner
without motor
(code 275400)
User for cleaning the
hearth