Electrical Installation
5.3

Assignment of RES plug

R = Receiver
Pin no.
Colour
Designation
1
White
nc
2
Brown
+ 24 V DC
3
Green
nc
4
Yellow
nc
5
Grey
RES SEL
6
Pink
RES
7
Blue
GND
8
nc
Fig. 5-5: Plug assignment for extension plug of C 2000 and M 2000 receiver
(RES/EDM), nc = not connected
© SICK AG • Safety Systems • Germany • All rights reserved
Meaning (I = Input, O = Output)
Vacant
O: Control voltage for reset button
Vacant
Vacant
I: GND = Reset deactivated
nc = Reset activated
I: Restart inhibit, connection for NO
contact (with respect to 24 V) of reset
button
0 V, Voltage supply
Vacant