Nuova Simonelli Aurelia Vip Plus Manual De Instrucciones página 66

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

9.
AURELIA PLUS MACHINE FUNCTION MESSAGES
DISPLAY AND KEY
INDICATIONS
DIAGNOSIS OF ERROR
DELIVERY ERROR
DOSER ERROR
LEVEL ERROR
PRESSURE ERROR
64
CAUSE
At the time of the diagno-
The machine will not
sis the system presents
heat and all its functions
faults within the control
will be blocked.
unit EPROM.
On reaching delivery
The display indicator and
time limit (120 seconds)
the 'continuous' key
the doser doesn't send
belonging to the relative
out its set commands.
unit will flash on and off.
If the doser doesn't send
If the delivery isn't
out its set commands
manually halted, the
within the first three
maximum time limit (120
seconds from delivery
sec) will be blocked.
onset.
If after 90 sec of machi-
The display indicator will
ne functioning the water
flash on and off. The
level is not re-establis-
pump is de-activated.
hed.
The resistor and all the
functions are halted.
When the machine's
The display indicator
temperature is higher
will flash on and off and
than 130°C.
the resistor is de-acti-
vated.
EFFECT
SOLUTION
Press the
key or one of the keys
Press the
key or one of the keys
Turn the machine off
and then turn it on
again. All its functions
will be re-activated.
The system will be re-
established as soon as
the temperature goes
below 130°C.
NOTES
The boiler is provided
with a manual refitting
safety thermostat; if the
resistor is not re-esta-
blished, call a qualified
technician.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aurelia vAurelia esse

Tabla de contenido