PROBLEM
Pressure
setting is too
HIGH/LOW pressure control set too high
low
Paint station
Paint container is empty or intake tube is
starts but does
not fully submerged in fl uid
not circulate
paint when
Suction fi lter is clogged
Prime/Spray
lever is turned
Prime/Spray valve is clogged
to Prime
Motor seems
Reversible spray tip is worn
to be running
properly but
Spray tip is clogged
pressure drops
when pistol-grip
Suction tube and fi lter are loose or damaged
is triggered
Pistol-grip sprayer fi lter is clogged
Material being sprayed is too thick
Inlet valve is damaged or worn
Intake tube is loose
Prime/spray lever
Prime/spray lever is dirty or damaged
is set to spray
but there is fl ow
through the prime
tube
Pistol-grip
Internal sprayer parts are worn or damaged
sprayer leaks
Nozzle tip guard
Nozzle tip guard or spray tip where
leaks
assembled improperly
Pistol-grip
Spray tip is clogged
sprayer will not
spray
Pistol-grip sprayer fi lter is clogged
Spray tip is not fully seated into nozzle tip
guard
Paint pattern is
Pressure is set to low
weak or uneven
Pistol-grip sprayer or intake tube fi lter is
clogged
Intake tube is loose at inlet valve
Spray tip is worn
Material being sprayed is too thick
Loss of pressure
IT
NL
PT
DK
SE
TROUBLESHOOTING
CAUSE
FI
NO
RU
PL
CZ
English
Turn HIGH/LOW pressure control clockwise
Fill paint container with material and submerge intake tube into
material
Clean suction fi lter
Contact Authorized Service Center
Replace spray tip
Turn spray tip 180° and spray to clean
Reinstall or replace suction tube and fi lter as needed
Clean or replace pistol-grip sprayer fi lter
Follow material manufacturer's directions and thin material as needed
Replace inlet valve
Tighten intake tube
Contact Authorized Service Center
Contact Authorized Service Center
eassemble according to nozzle tip guard and Spray tip assembly
instructions
Turn spray tip 180° and spray to clean
Clean or replace pistol-grip sprayer fi lter
Reassemble according to nozzle tip guard and Spray tip assembly
instructions
Turn High-low pressure knob clockwise to increase pressure
Clean or replace fi lters
Tighten tube fi tting
Replace spray tip
Follow material manufacturer's directions and thin material as needed
See Cause/Possible solutions for "Pressure setting is too low," and
"Motor seems to be running properly but pressure drops when
pistol-grip is triggered"