6.4 Approximate values when using pulsation
dampers
Risk of damage to the system!
It is always recommended to use pulsation dampers
for large high-speed pumps!
Caution
Since the pulsation is influenced by many factors, a
system-specific calculation is essential. Request a
calculation from our calculation program.
The table below indicates the approximate values and the suction
line length for which suction pulsation dampers are required. The
values apply to 50 Hz operation when water or similar liquids are
dosed.
Stroke rate
Pump type
[n/min]
DMH 280
DMH 0.6-200
29
DMH 1.3-200
63
DMH 2.2-200
96
DMH 2.5-200
120
DMH 3.3-200
144
DMH 281
DMH 2-100
29
DMH 4.2-100
63
DMH 6.4-100
96
DMH 8-100
120
DMH 9.6-100
144
DMH 283
DMH 10-100
26
DMH 19-100
54
DMH 27-100
75
DMH 33-100
92
DMH 40-100
112
DMH 55-100
153
DMH 285
DMH 20-100
28
DMH 40-100
56
DMH 52-100
73
DMH 70-100
98
DMH 80-100
112
DMH 105-100
146
DMH 286
DMH 170-50
112
DMH 222-50
146
DMH 85-50
56
DMH 111-50
73
20
Maximum
Nominal
length of
width of
suction line
suction line
[m]
DN 4
8
DN 4
8
DN 4
8
DN 4
8
DN 4
8
DN 8
8
DN 8
8
DN 8
8
DN 8
8
DN 8
8
DN 20
8
DN 20
8
DN 20
8
DN 20
8
DN 20
8
DN 20
6
DN 20
8
DN 20
8
DN 20
8
DN 20
6
DN 20
5
DN 20
3
DN 20
2.5
DN 20
1.5
DN 20
2.5
DN 20
2.5
Stroke rate
Pump type
[n/min]
DMH 287
DMH 9-200
28
DMH 18-200
56
DMH 23-200
73
DMH 31-200
98
DMH 36-200
112
DMH 50-200
146
DMH 288
DMH 3-200
26
DMH 7.5-200
54
DMH 10-200
75
DMH 13-200
92
DMH 15-200
112
DMH 21-200
153
Maximum
Nominal
length of
width of
suction line
suction line
[m]
DN 8
8
DN 8
8
DN 8
4
DN 8
3
DN 8
2
DN 8
1
DN 8
8
DN 8
8
DN 8
4
DN 8
3
DN 8
2
DN 8
1