ELGA-TB-G/-KF/-RF
Amount of lubricant at each relubrication opening:
Size
Amount of lubricant
Grease for ELGA-KF
Oil for ELGA-RF
Tab. 4
8
Disassembly and repair
WARNING
Unexpected movement of components.
Injury due to impacts or pinching.
When working on the axis, switch off the control unit and secure it to prevent it from
being switched back on accidentally.
Observe notes on transport (è 4 Transport).
If repairs are required:
Send axis to Festo or contact your local Festo service centre (è www.festo.com).
Festo carries out the required repairs, fine adjustments and checks.
Information about spare parts and accessories (è www.festo.com/spareparts).
9
Disposal
At the end of the product service life, package up and send the axis away for environmentally appro
priate disposal.
40
70
[g]
0.4
[ml]
1.0 ... 1.5
80
120
0.8
2.0
1.5 ... 2.5
2.5 ... 4.5
Festo – ELGA-TB-G/-KF/-RF – 1512d English
150
3.4
–