Expert Inspection - CRESTO RESQ RED PRO Mk I Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 202
9. LINE DURABILITY/SERVICE LIFE
Depending on type, the supplied line has a maximum service life of 4 to 6 years.The line's
service life strongly depends on where and how the line is used and stored and must there-
fore be assessed on each occasion by an expert.
Unused line that has been stored in vacuum packing has a guaranteed life of 10
years.
Inspection and any replacement of the device's lines must be carried out by an expert and
must be documented using the supplied control card, which must always be kept with the
REDPro™ Mk I rescue and evacuation device. The date for the next expert inspection must
be clearly visible on the control card and the device and box inspection labels.

10. EXPERT INSPECTION

Inspection and service of the equipment must be carried out by an expert at least once
every 12 months, and the manufacturer's instructions. NOTE: Be advised that some coun-
tries require mandatory inspection every 6 months.
These regular periodic examinations must ensure the safety of users as continued ef-
ficiency and durability of the equipment depends on this continued procedure.
NB: Training equipment must be inspected by an expert after every training session.
Inspection and any replacement of the line must be carried out by an expert and must be
documented using the supplied control card, which must always be kept with the equip-
ment.
Authorisation institute
Type certification and approval is carried out by:
DEKRA EXAM GmbH,
Dinnendahlstr. 9, 44809 Bochum, Germany –
0158 EN 341 class A.
CSA International, Toronto, Canada
259.2.3-99 (R2004), type 1E.
| 15
© CRESTO AB 2016 | UK Master vers. 2016 - 1 | Rev. 21.06.2017

Publicidad

Tabla de contenido
loading

Productos relacionados para CRESTO RESQ RED PRO Mk I

Tabla de contenido