10.FAULTS, CAUSES AND REMEDIES

Only have faults remedied by qualified personnel! Follow the
safety instructions in 9 Maintenance.
Fault
Pump does not start
Safety switches thrown
Pump has no power
If the operating fault cannot be remedied, please get in touch
with the trade outlet or the nearest customer service or agent.

11.SPARE PARTS

Spares are ordered through local trade outlets and/or the
SalmsonAfter-Sales Service.
To avoid queries and incorrect orders, always provide all of the
details on the name plate with every order.
Subject to change without prior notice !
Cause
No voltage
Rotor blocked
Fuses, condenser defective (1~)
Cable rupture
Water in the motor chamber
Foreign bodies in the pump, winding protec-
tion contact triggered
Pump sucking air because the fluid level has
dropped too far
Pressure pipe plugged
19
Remedy
Check the wires and fuses, or switch auto-
matic fuses in the distribution station back on
Clean the housing and impeller, if still blocked
replace the pump
Replace fuses, condenser
Check cable resistance. If necessary,
change the cable. Only use original special
cable!
Ask After-Sales.
Switch off the installation and prevent it from
being switched on again, lift the pump out of
the pit.
Remove the objects.
Check the function/setting of the level con-
trol
Detach the pipe and clean it

Publicidad