Connections
Connecting the mains voltage
Live parts
Risk of fatal injury due to electric shock
when touching live parts.
- Switch off mains voltage.
- Protect against re-connection.
Both the power supply and the related connection
work must comply with national standards, e.g. those
set up by VDE in Germany. The connection work must
only be performed by qualifi ed expert staff.
The connection to the 400 V mains must be protected
by fuses. Their specifi cations are listed in the chapter
"Technical data".
A residual current-operated circuit breaker (RCD) is
absolutely required. KBL-Solarien AG recommends
the following type: KBL 3200 0770 00 (type ABB F
374 63/0.03A)
Should the operation of the tanning unit cause any
interference in the power supply network, e.g. with
ripple-control systems (TRA), consult your power
supply company to have corresponding blocking
elements (audio frequency suppressors) installed.
Figure 8.1
mains connection
400V / 3N / 50Hz coupling box with fuses
and residual current operated circuit
breaker of type ABB F 374 63/0,03A (KBL
3200077000)
PE L1 L2 L3 N
8