GiBiDi SC24 Manual De Instrucciones página 11

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
SC24
ELECTRICAL CONNECTIONS: FASTONS
Position
Signal
1
0 Vac
2
18 Vac
3
24 Vac
ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
2
+24 Vac
3
+SK BAT
4
-SK BAT
M1
5
6
7
8
9
10
START
11
M2
12
PHOTO
13
SAFETY
14
15
MOTOR OPEN
16
MOTOR CLOSE
17
+ ACCES
M3
18
+ SAFETY
19
20
21
22
M5
23
PROTECTION FUSES
Position
Value
315 mA
F1
FAST-BLOW
F2
5 A
FAST-BLOW
F3
500 mA
FAST-BLOW
Description
Transformer 0 Vac connection (black cable).
Transformer 18 Vac connection (orange cable).
Transformer 24 Vac connection (red cable).
Signal
Description
0 Vac
0 Vac output to the BATTERY CHARGER BOARD.
24 Vac output to the BATTERY CHARGER BOARD.
Positive connection to the BATTERY CHARGER BOARD.
Negative connection to the BATTERY CHARGER BOARD.
Flashlight output 24V 10W max (slow flashing during opening, off with gate open, fast
LAMP
flashing during closing); it can also be connected to the battery charger board.
Warning light output 24V 3W max (slow flashing during opening, on fixed with gate
SPIA
open, fast flashing during closing).
Common INPUTS - OUTPUTS.
COM
Not used.
OPT
STOP
STOP input (N.C.). If not used, jumper with terminal 14.
START input (N.O.).
PEDESTRIAN input (N.O.).
PED
PHOTOCELL input (N.C.). If not used, jumper with terminal 14.
SAFETY DEVICE input (N.C.). If not used, jumper with terminal 14 and set DIP 4 to OFF.
Common INPUTS - OUTPUTS.
COM
24V motor output - open.
24V motor output - close.
+24 Vdc external accessory power supply (photocells, radio, etc.).
24 Vdc power supply for external safety devices (frame), active only during the
operating cycle; connect the devices on which to run the safety test to this input (also
see DIP 4).
COM
Common INPUTS - OUTPUTS.
Opening limit switch input.
FCA
Closing limit switch input.
FCC
GND
NTENNA BRAID input.
ANTENNA SIGNAL input.
ANT
Type
Description
Protects the ACCESSORY and SAFETY DEVICE power supply.
Protects the control unit at the 24 VAC power supply input.
Protects the flashlight output.
N.B. Do not connect if the board is assembled
on the operator.
11