6. Installing the unit
CAUTION
All installation operations must comply with current regulations.
All operations involving moving heavy weights must be carried out by two people.
Before installing the unit, the packaging must be removed, taking special care not to damage the housing.
Check that there is no condensation inside the packaging. If there are signs of condensation, the unit must not be
installed until you are sure it is completely dry.
6.1. General requirements for installation
•
The environment of the unit must be appropriate and meet the guidelines described in chapter
Preparation for installing the
compatible with the unit and comply with the applicable legislation.
•
The ventilation and workspace must be suitable for maintenance tasks according to the applicable
regulations in force.
•
The external connection devices, which must be suitable and sufficiently close as set forth in current
regulations.
•
The feed cables must be of the appropriate gage for the maximum current.
•
Special care must be taken to ensure that there are no external elements near the air inlets and outlets
that obstruct proper cooling of the unit.
6.2. Attaching the unit to the wall
INGECON SUN STORAGE 1Play units have a system for securing them to the wall using a plate. The steps for
fixing the unit properly are as follows. The weight of the unit must be taken into account.
1.
Mark the fixing points for the plates on the wall and drill holes with a suitable bit for the screws to be
used to secure the plate to the wall later.
22
unit". Additionally, the parts used in the rest of the installation must be
80
200
80
ABH2014IQM01_A- Installation and Operation Manual
Installing the unit
"5.