B B E E F F O O R R E E S S T T O O R R I I N N G G Y Y O O U U R R S S M M O O K K E E R R : :
• Clean all surfaces.
• When cool and not in use, store your smoker indoors in a dry location to protect against
rusting.
• If storing the smoker outdoors, cover the smoker with a smoker cover for protection from
the weather.
PROBLEM
BURNER
Fire at
control
knob
Yellow
Flames
at burner
Flame
blows
out on
"LOW"
Burner does
not get hot
enough
Smoker is
too hot
15
S S T T O O R R A A G G E E
T T R R O O U U B B L L E E S S H H O O O O T T I I N N G G
CAUSE
1. Check LP cylinder fuel level.
2. Bad electrode spark.
3. Burner may not be properly seated.
4. Burner may be obstructed.
5. The cylinder valve may be closed.
6. Regulator is not properly seated on
cylinder valve.
1. Burner holes may be obstructed.
2. Burner is improperly seated on
control valve.
3. Gas connections may be loose.
1. Burner is obstructed.
1. Burner holes may be obstructed.
2. Burner is improperly seated on
control valve.
3. Grill is not sufficiently pre-heated.
1. Flow control device has been
activated in regulator.
1. Excess grease build-up causing
grease fires.
2. Damaged or faulty regulator.
3. Cook on a lower temperature
setting.
SOLUTION
1. Replace LP Cylinder.
2. Check to see if the smoker will match
light.Electrode or collector may need
adjustment.
3. Reseat burner.
4. Clear obstructions from burner.
5. Open cylinder valve.
6. Reseat regulator on cylinder valve.
1. Clear obstructions from burner.
2. Reseat burner on control valve.
3. Leak check and tighten all connections.
1. Clear obstructions from burner.
1. Clear obstructions from burner holes.
2. Reseat burner on control valve.
3. Pre-heat smoker sufficiently.
1. Reset regulator by turning off gas at LP
cylinder. Disconnecting regulator from
tank. Re-attaching regulator to tank.
1. Clean smoker components thoroughly.
2. Replace with factory authorized parts.
3. Lower flame height and temperature.