If there is a question on the identity of your unit and of the type of fuel to be used,
please look on the data plate. Units are factory equipped for use on only one type of
fuel. These units cannot be, and should not be used on other type of fuels. Doing so can
cause severe damage to the unit and the installation area and the added risk of serious
injury. Any attempt to operate these smokers on fuels for which they are not design
certified voids the manufacturer's warranty.
Gas Tank outlet must have Type 1 gas connection termination in order to mate with gas
hose provided with smoker.
The pressure regulator and hose assembly supplied by the manufacturer with the
appliance must be used. Replacement pressure regulators and hose assemblies must
be those specified by the appliance manufacturer.
The regulator/hose assembly should be handled carefully to prevent contamination by
foreign objects and dirt. Clean and inspect the hose before each use of the appliance. If
there is evidence of abrasion, wear, cuts or leaks, the hose must be replaced prior to the
appliance being put into operation. In order to insure proper operation, any replacement
of the fuel tank regulator assembly has to be done with parts authorized by the smoker
manufacturer.
This unit is not to be utilized with a non-self-contained LP-gas supply system.
Valve/pressure regulators are factory set to the correct operating pressures.
No attempts should be made to adjust these settings!
C C O O N N N N E E C C T T I I N N G G T T H H E E L L P P T T A A N N K K : :
ALL INSTRUCTIONS AND SAFEGUARDS ON THIS PAGE MUST BE FOLLOWED TO
PREVENT FIRE, DAMAGE, AND / OR INJURY.
1. The knob on the LP tank must be closed. See that the knob is turned clockwise to a full
stop.
2. Check that control knob on the smoker is turned off.
3. Remove the protective cap from the LP tank valve and
coupling nut, if present.
4. Hold the regulator in one hand and insert the nipple into
the valve outlet. Be sure the nipple is centered in the valve
outlet. The coupling nut connects to the large outside threads
on the valve outlet.
Note: Use care - do not cross thread the connection.
5. Hand tighten the coupling nut clockwise until it comes to a
full stop. Firmly tighten by hand only. Do not use tools.
CAUTION: In the connection process, the hose/regulator side of the connection will
seal on the back check in the valve, resulting in a slight resistance. The
connection requires about one-half to three-quarters additional turn to
complete the connection.
7
WARNING
WARNING