Unit description
2.9. Specification table
Power Analyzer
Voltage and current metering accuracy
Frequency metering accuracy
Power and energy metering accuracy
Power factor metering accuracy
THD metering accuracy
Voltage harmonics metering
Current harmonics metering
Nominal value of the voltage metering input
Nominal value of the current metering input
Other measurements
Production quality registration (PQ)
Redundancy
Power Supply
Voltage supply
Typical consumption
Maximum consumption
Input fuse
Autonomy in case of a supply cutoff
Redundancy
Communication
Standard protocols
Compatible protocols
Outer connectivity
Managed communication
Redundancy
Regulation
Production Control
Grid Support
Grid Code Configurations
Active power
Reactive power
O&M Functions
Datalogger
Equipment start up / stop
Power plant surveillance
Others
CPU
Typical processing time
Clock
Surveillance system
Redundancy
General Data
Dimensions (H/W/D)
Weight
Protection class
Impact resistance
Overvoltage protection
Installation
Operating temperature
Storage temperature
Relative humidity
Maximum altitude
Marking
Standards
Notes:
For voltages greater than 30% of the nominal voltage
(1)
the autonomy is 2 seconds.
ABP2011IQM01_ - Installation and Operation Manual
Standard version
Up to level 40
Up to level 40
Short- and Long-term Flickers / unbalances
Not available
85 Vac ... 264 Vac, 50 Hz ... 60 Hz / 99 Vdc ... 275 Vdc
33 W
50 W
Not available
Modbus / TCP, FTP, NTP
Modbus / RTU, 101 (Server), 104 (Server), DNP3 (Server), OPC UA
10 / 100BaseT(X), 100BaseFX (MM) with patch panels
Optional
Not available
On-Demand Production, Active Power Reserve, Ramp Rate Control, Energy Time Shifting, Peak Shaving
Digital Q Compensation, Power Factor Control, Automatic Voltage Regulation
1 month data storage in Compact Flash memory with 1 s sampling
General start up or stop of the inverters, BESS and capacitor banks
Monitoring of the status of every single element inside the plant
Internal RTC sinchronizable through NTP
Watchdog, working times surveillance, CPU temperature and input/output status
Not available
855 / 600 / 360 mm
40 kg
IP65
Wall
-10 / 45 ºC (14 / 113 ºF)
-20 / 60 ºC (-4 / 140 ºF)
IEC 61000-4-30, IEC 62586-1, IEC 61131-3, IEC 60204-1, IEC 61439
Values measured with the highest redundancy level
(2)
Premium version
Class 0.2 S
10 mHz
(1)
Class 0.5 S
Class 1 S
Class 0.5 S
110 Vac
5 Aac
Optional
Optional
120 W
(2)
280 W
(2)
6.3 A
20 min
(3)
Optional
Yes, with SNMP v1/2/3, VLAN, DHCP, Flow control, STP, MAC filter
Optional
PvsF
QvsV, QvsP
Web server
10 ms
Optional
2.150 / 800 / 800 mm
150 kg
IP5
IK10
Type 2
Ground
10 / 95%
2,000 m
CE
If the installation features an energy storage system. Otherwise,
(3)
Ingeteam
EN
ES
11