Troubleshooting (continued)
Caution
!
Avoid contact with hot adhesive,
cartridge, applicator tip, and metal
components. May cause burns.
IMPORTANT: Wear heat resistant
gloves and safety glasses when using.
22
3M™ Scotch-Weld™ Polyurethane Reactive (PUR) Easy 250 Adhesive Applicator User's Manual
4. Inspect the 3M™ Scotch-Weld™ Polyurethane Reactive (PUR) Easy 250 or
3M™ Scotch-Weld™ Polyurethane Reactive Adhesive Cartridge for dents or
damage and replace with an undamaged cartridge. Dented or damaged
cartridges will not allow a proper seal and air will leak past the cartridge.
5. If air leak occurs at connections on the end cap, disconnect air service and
tighten connections.
6. If the connections or air line is damaged or broken, replace with air valve
assembly 62-9845-0009-0.
7. If air supply line has been cut or damaged, replace air supply line
62-9895-0005-3.
8. If air leak occurs inside the handle, the two handle halves must be separated by
following the disassembly procedure, page 23.