19. Lift and rotate the housing 180 degrees clockwise so both sides are open and
all components are visible.
20. Reconnect air supply set at 30-40 psi maximum to help locate air leak.
21. Inspect connections and retighten if necessary. If air valve is leaking or air line
going to end cap is leaking or has been damaged, replace with air valve
assembly 62-9845-0009-0.
22. If air supply line has been punctured, cut or has been disconnected from air
valve assembly, replace or reconnect air supply lines or replace with air supply
line 62-9895-0005-3.
23. After inspecting, tightening loose fittings, or replacing parts, reassemble handle
halves by following Reassembly Instructions. See page 36.