WARNING
!
Disconnect air and electrical power
and make sure applicator has cooled
to room temperature before servicing.
Failure to disconnect air and electrical
power or failure to allow applicator to
cool before servicing may cause
electrical shock or burns. Read
User's Manual before servicing.
© 3M 2014
Disassembly Procedure
3. Remove wire stand by pulling one side just enough to clear wire out of its pivot hole.
Let the wire settle into the recess just forward of the pivot hole location.
4. Do the same with the opposite side of the wire stand.
5. Pull either side of the wire stand over the housing, preferably at the lowest point –
which is the small groove at the front. Remove the wire stand and set aside.
6. Remove end cap by turning counterclockwise.
7. If possible, remove cartridge and nozzle.
8. Lay applicator on side so screw heads face upward.
3M™ Scotch-Weld™ Polyurethane Reactive (PUR) Easy 250 Adhesive Applicator User's Manual