FIXING THE SANICUBIC 1 UNIT TO THE FLOOR
8h
The SANICUBIC 1 unit is equipped with fittings to hold it
on the floor and
prevent it from turning or moving.
1- Place the unit on the desired spot.
2- Locate the 2 holes for attachment to the floor.
3- Place the 2 pins [A] on the floor then replace the appliance.
4- Fix the unit in place with the screws.
ELECTRICAL CONNECTIONS
8i
1- The electrical installation work must be carried out by a
qualified electrician.
The electrical installation must comply with the standards in
force in the country concerned
2- The power supply must be of the class 1 type. The unit must be
connected via an earthed connection box. The electric power
circuit must be protected by a high-sensitivity 30 mA differential
circuit breaker set at 20 A. The connection must be used solely
to power the SANICUBIC 1. If the power lead on the unit
is damaged, it must be replaced by the manufacturer or its
after-sales service to avoid all danger.
9

ALARM OPERATION

1/ General alarms:
High level alarm:
If the water level inside the appliance is unusually high, the red
alarm LED will light up.
Time alarm:
If the motor runs for over 1 minute, the red alarm LED will
light up.
2/ Resetting the general alarms:
The control panel button can only switch off the red LED
(it turns green) if the problem causing the alarm is resolved.
3/ Mains alarm:
If the green LED on the control panel is flashing, it means that
the mains electrical power has temporarily been cut off.
UNIT ALARM
LED
GREEN : under power
RED : Alarm
TOUCH
Override motor
RESET Alarm
1 0
CONFORMITY WITH STANDARDS
complies with standard EN 12050-1 (lift
SANICUBIC 1
station for household waste containing faeces) and with the
European directives covering construction products, electrical
safety and electromagnetic compatibility
This unit must be installed and used in compliance with
European installation standard EN12056 and with local
requirements.
1 1
COMMISSIONING
1- Once the plumbing and electrical connections have been
made, check that the connections are watertight by
letting water flow successively through each inlet used.
Make sure that the unit is operating correctly by carrying
out at least two start cycles with water to test the system.
2 -
WARNING!
When connected to the power supply, the
green "mains" LED will flash. Press the button on the
control panel and the green LED will show
continuously. Operation without water damages the
maceration system.
1 2
USE
1- The
SANICUBIC 1
unit is designed to drain off
household waste water. Any other use will invalidate the
guarantee. Do not dispose of sanitary towels, condoms,
hygiene articles, oils, solvents, acids, or any other poten-
tially corrosive or explosive liquids etc., via the unit.
2-
WARNING: In the event of a power failure, stop
draining any water from the equipment connected
to the SANICUBIC 1 unit.
3- Do not install or use the unit in a zone where there is a
risk of explosion.
1 3
MAINTENANCE
A visual check of the lift station must be made once a month
to make sure it is operating correctly, and the installation
must be inspected regularly (once a year) by a qualified
person. Meanwhile if encounter technical problems, please
ask our after-sales service for advice. If the power supply
cable of the unit is damaged, it must be replaced by the
manufacturer or its after-sales service to avoid all danger.
1 4