5.3

Key function

Key
Function
F1
Reset measurement.
F2
Backwards
F3
Forwards
F4
Back to the main me-
nu
Tab. 5:
Function keys
i
The availability of the function keys depends on the
content of the dialog boxes.
5.4

Navigation bar

Icon
Status / function
Call up help.
Return to last step
Forward to next step
Back to the main menu
Reset measurement
Switch off program
Print
Search
Program version
Tab. 6:
Status messages
Robert Bosch GmbH
Key
Function
F5
Help
F6
Print
F7
Measurement
raised
Ctrl + F3
Deactivate run-out
compensation (in
the program win-
dow run-out com-
pensation)
Operation | FWA 6620 / 6720 / 6820 | 45
5.5

Program structure

5.5.1
Program functions
Icon
Function
Visual inspection
Program-driven measurement
Quick measurement
Random measurement
Program settings
Tab. 7:
Program functions
5.5.2
Program measurement
Icon
Measurement
Steering angle routine:
R Measure castor.
R Measure steering axis inclination.
Rear axle:
R Measure and adjust left and right camber.
R Measure and adjust left and right toe.
Castor setting:
R Adjust castor.
R Correct left and right camber.
R Correct left and right toe.
Front axle:
R Measure and adjust left and right camber.
R Measure and adjust left and right toe.
Tab. 8:
Measurement function
5.5.3
Measured value display
i
The arrow above the numerical display compares the
current value to the setpoints. The measured value
is indicated underneath.
Display
Background: green
Background: red
en
Status
The measured value is in the
range of the manufacturer's
recommendation.
The measured value is out-
side of the range of the
manufacturer's recommen-
dation.
|
1 690 706 113