Descargar Imprimir esta página

Bosch FWA 6620 Manual Original página 51

3d 2cam indicador de alineación de ejes

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 88
5.7.8
Measuring the rear axle value
1. Bring steering wheel in center position.
2. Insert the steering wheel arrester.
3. Select <Continue>:
Abb. 45: Steering wheel center position
Abb. 46: Rear axle data
 The measurement screen shows the single toe,
camber and total toe values.
4. Select <F3> or <Continue>:
 Castor is displayed.
5.7.9
Adjusting castor
Abb. 47: Castor measurement
 The measurement screen shows the camber, cas-
tor and toe values.
5. Select <F3> or <Continue>:
 Front axle values are displayed.
Robert Bosch GmbH
Operation | FWA 6620 / 6720 / 6820 | 51
5.7.10
Measuring front axle values
Abb. 48: Front axle values
 The measurement screen shows the camber, sin-
gle toe and total toe values.
Zoom-in single value by double-click.
5.7.11
Adjust in raised position
1. Select
.
2. Lift vehicle axle.
3. Select <F3>:
 Vehicle measurement is continued in raised posi-
tion.
i
Accessing the test protocol in lifted condition is not
possible.
4. Adjust camber and toe.
5. Select
.
 Vehicle measurement in raised position is fina-
lized.
6. Lower vehicle axle.
7. Deflect vehicle.
en
|
1 690 706 113
2017-10-11

Publicidad

loading

Este manual también es adecuado para:

Fwa 6720Fwa 6820