RISK OF FIRE OR ELECTRIC SHOCK
• Do not install this modular system across building floor expansion joints.
• Do not install this system on raised flooring.
• Do not install this system in an area where it will be subjected to constant or rolling loads heavier than
people.
• Ensure that panel systems, wall systems (V.I.A. or Privacy Wall) or systems furniture is not installed on
top of the Power Track Infeed, Power Track, or Connectors.
• All hinged cover doors must be free from obstructions and allowed to close fully after installation.
• Disconnect unit from power before assembly or disassembly.
• Do not modify parts. No user serviceable parts inside the system.
TRIP AND FALL HAZARD
• NEMA Monument height can cause tripping, do not install in circulation paths. Review layout with architect or designer to verify
circulation paths.
• Carpet plus pad thickness must be between 0.225 and 0.450 inches to minimize risk of trip and fall especially at Blank, One Door,
Ca
an
and Two Door Low Profile Connectors. Luxury vinyl tile must be between 0.100 and 0.250 inches and must use a 5mm inflexible
underlayment installed.
• Do NOT use finished flooring other than carpet squares, rolled carpet, luxury vinyl tile, or other conformable type flooring.
• Not Approved for use in Hospital Patient Care Areas or other spaces where Hospital Grade receptacles are required.
• The Blank, One Door, and Two Door Low Profile Connectors can be located in circulation paths and meet accessibility
requirements as long as the carpet plus pad thickness is between 0.225 and 0.450 inches or luxury vinyl tile flooring is
between 0.100 and 0.250 inches plus underlayment.
• Do not exceed maximum 70 ft in overall length.
WARNING
CAUTION
NOTICE
Page 3 of 75
24207101 Rev G