(FOR INSIDE WALL MOUNTING)
POWER TRACK INFEED INSTALLATION
3b.
• Locate studs in wall and plan power track infeed housing to be located between studs.
• Remove base trim to expose wall where power track infeed will enter the wall. Cut hole in the wall large enough so that housing and infeed wire can be placed
inside the wall. This may include locally removing steel or wood bottom plate.
• The electrician must now locate the most convenient junction box or install a new junction box. Connect the power track infeed to this junction box.
NOTE: This circuit must be protected by a listed 120 V~, 20A GFCI device.
• At this point, the electrician should have the ability to install the building power to the junction box without making the final connection to the power track infeed.
• All debris must be removed from inside the wall and on the floor to ensure the power track infeed rests flat on the sub-floor.
• Position the power track infeed housing inside the wall in its approximate final location. Verify that one of the four anchor holes on each end of the track is
accessible during installation of anchor screws.
NOTE: A portion of each ramp will need to be removed when choosing an inside wall mount. This can be accomplished by marking a line where the ramp ends
at the wall and cutting with a utility knife.
STUD
BASE
PLATE
DRYWALL
3b
CONDUIT
NOTCH THE DRYWALL AND
BASE PLATE TO A DIMENSION
OF 4" WIDE x 4" HIGH
NOTE: DO NOT cut
into the wall studs.
BEFORE INSTALLING RAMPS,
TRIM WITH A UTILITY KNIFE SO
RAMPS ARE FLUSH TO THE WALL
Page 9 of 75
24207101 Rev G