Grounding - Franklin Electric SubDrive75 Guía De Instalación Rápida

Ocultar thumbs Ver también para SubDrive75:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Grounding

Ensure that a
proper utility
ground rod
is present &
connected.
GND
GND
6
Service Entrance
Panel
L1
L2
GND
An input power ground wire from
the supply panel must be connected
to the drive.
Service entrance
ground rod
Service Entrance
Panel
GND
GND
Pump
Motor
Ensure that a
proper utility
ground rod
is present &
connected.
Service Entrance
Use the service
GND
entrance panel
ground ONLY.
Avoid multiple ground paths.
A dedicated output ground wire
from the drive must be connected
to the motor (motor wires and ground
wires must be bundled together).
Service Entrance
Panel
GND
L1
L2
GND
Pump
An input power ground wire from
the supply panel must be connected
to the drive.
Service entrance
ground rod
Motor
Panel
GND
Pump
Motor
A dedicate
from the d
to the mot
wires mus
GND
Service Entrance
Panel
Use the service
entrance panel
ground ONLY.
DO NOT run ground wire separate