5.2.5 Draining the condensate
Daily drain the condensate from tank through the drain tap (see ref.3 on page 3).
The condensate drained is considered as polluting mix that must not be thrown away outdoors. It is advisable to use
special water/oil separators for its disposal in accordance with applicable laws
◊ 5.3
Pneumatic circuit
Always use pneumatic hoses for compressed air with the maximum pressure characteristics and cross section suitable
for those of the compressor. Do not try to repair a faulty hose.
◊ 5.4
Diagnosing the alarm status/inconveniences-faults
COMPRESSOR
System not in pressure or
non continously pressure
Noisiness from the tank.
Abnormal
consumption
of oil
Metallic noise
The compressor run but
not load.
ENGINE
Engine failure
Engine stops
GENERATOR
No voltage to electrical
sockets
Air filter clogged
Pump unit head gasket dama-
ged
Connections air leacks and/or
pneumatic hoses or damaged
head valves.
Hoses clogged
Defective segments.
Oil flow through the segments.
(Oil presence in condensate
drain hose)
Loosen or break belt
Defective discharge valve
Defective security valve or
pressure too hight.
Damaged mechanics elements.
Loose or damaged mechanic
element
Damaged valve plate or air le-
aks.
Refer to the engine manual.
Oil temperature too hight.
The magneto thermal circuit
breaker switch on.
Loose or damaged belt
Wrong rotation speed of ther-
mal engine.
Generator failure
Check and eventually replace the air filter
Replace the head gasket
Replace the defective elements
Check and clean or eventually replace the hoses.
Replace segments
Tighten or replace the belt
Replace the discharge valve
Replace the security valve
Check and replace the damaged mechanins ele-
ments by an Authorised Service Centre.
If the problem persist contact an Authorised Service
Centre.
Repair to an Authorised Service Centre.
Check the oil level.
Check if the fan in-take grid is clean or obstructed.
f the problem persist contact an Authorised Service
Centre.
Disconnect the power tools from the sockets and
reset the magneto thermal switch.
Tighten or replace the trasmission belt.
Please, contact an Authorised Service Centre.
Please, contact an Authorised Service Centre.
19
EN
EN