INTRODUCTION
EN
This instruction sheet provides you with the information required to safely own
and operate your product. Retain these instructions for future reference.
The product you have purchased is of the highest quality workmanship and
material, and has been engineered to give you long and reliable service. This
product has been carefully tested, inspected, and packaged to ensure safe
delivery and operation. Please examine your item(s) carefully to ensure that no
damage occurred during shipment. If damage has occurred, please contact the
place of purchase. They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL, OPERATE, OR SERVICE YOUR PRODUCT. KNOW THE PRODUCT'S
APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION.
FAILURE TO COMPLY WITH THESE INSTRUCTIONS COULD RESULT IN
PERSONAL INJURY AND/OR PROPERTY DAMAGE!
DESCRIPTION
Little Giant Submersible 20S Series Sewage Ejector Pumps and 20E Series Effluent
Pumps are recommended for use in basins or lift stations and suitable for pump-
ing sewage, effluent, wastewater and other non-explosive, non-corrosive liquids.
The S Series Sewage Ejector Pumps have 2" spherical solids handling capability.
The E Series Effluent Pumps have 3/4" spherical solids handling capability.
Little Giant offers a complete line of float switches and liquid level control sys-
tems for automatic operation along with a complete line of alarms, basins, cov-
ers, and check valves.
SPECIFICATIONS
Discharge Size:
20E and 20S — 2" or 3"
Handling Capabilities: E Series — 3/4" spherical solids
S Series — 2" spherical solids
Pump Housing:
Cast iron
Volute:
Cast iron
Impeller:
Non-clog brass with pressure relief vanes
Motor:
3200 RPM with automatic overload protection
Hardware:
300 Series stainless steel
Bearing:
Ball
Shaft Seal:
Mechanical, spring loaded, rotating carbon with Nitrile
boot and stationary ceramic seat, with secondary Nitrile
exclusion seal
Power Cord:
14 AWG 3-conductor, copper, stranded
Cooling:
The motor housing contains a cooling oil to provide
cooling for the motor and to lubricate bearings and
seals. These pumps are capable of operating with the
motor housing partially exposed for extended periods
of time, providing sufficient motor cooling and bearing
lubrication. However, for the best cooling and longest
motor life, the liquid level being pumped should normally
be above the top of the cast iron motor housing.
SAFETY GUIDELINES
WARNING: RISK OF ELECTRIC SHOCK. This pump is supplied with a ground-
ing conductor and grounding-type attachment plug. To reduce the risk of electric
shock, be certain that it is connected only to a properly grounded, grounding-
type receptacle.
When a pump is in a basin, etc., do not touch motor, pipes or water until unit is
unplugged or shut off. If your installation has water or moisture present, do not
touch wet area until all power has been turned off. If shut-off box is not acces-
sible, call the electric company to shut off service to the house, or call your local
fire department for instructions. Failure to follow this warning can result in fatal
electrical shock.
The flexible jacketed cord assembly mounted to the pump must not be modified
in any way, with the exception of shortening the cord to fit into a control panel.
Any splice between the pump and the control panel must be made within a
MODEL
CATALOG
NO.
NO.
HP
20S-CIM
520100
2
20E-CIM
520200
2
20E-CIM
20S-CIM
1 Phase
PH
VOLTS
HZ
AMPS
1
208-230
60
18.0
1
230
60
16.4
junction box and mounted outside of the basin, and comply with the National
Electrical Code. Do not use the power cord for lifting the pump.
The pump motor is equipped with an automatic resetting thermal protector and
may restart unexpectedly. Protector tripping is an indication of motor overload-
ing as a result of operating the pump at low heads (low discharge restriction),
excessively high or low voltage, inadequate wiring, incorrect motor connections,
or a defective motor or pump.
Read all instructions and Safety Guidelines thoroughly. Failure to follow the
guidelines and instructions could result in serious bodily injury and/or property
damage.
DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS
GASOLINE, FUEL OIL, KEROSENE, ETC. FAILURE TO FOLLOW THIS WARNING
CAN RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE.
During normal operation the sump pump is immersed in water. Also, during rain
storms, water may be present in the surrounding area of the pump. Caution must
be used to prevent bodily injury when working near the pump:
Electrical power should be disconnected prior to touching, servicing or
repairing the pump.
To minimize possible fatal electrical shock hazard, extreme care should be
used when changing fuses. Do not stand in water while changing fuses or
insert your finger into the fuse socket.
Do not run the pump in a dry basin. If the pump is run in a dry basin, the surface
temperature of the pump will rise to a high level. This high level could cause skin
burns if the pump is touched and will cause serious damage to your pump.
Do not oil the motor. The pump housing is sealed. A high grade dielectric oil
devoid of water has been put into the motor housing at the factory. Use of other
oil could cause serious electric shock and/or permanent damage to the pump.
Do not install in locations classified as hazardous in accordance with the National
Electrical Code, ANSI/NFPA 70.
For automatic operation, pump must be plugged or wired into a remote float
switch or liquid level controller. Installation instructions are included with all Little
Giant switches and controllers and should be referred to for installation.
Pump will run continuously if plugged directly into an electrical outlet. Care
should be taken to prevent pump running in a dry sump.
Pump must be installed in a suitable gas tight basin which is at least 24" in diam-
Figure 1
GPM @ HEAD
10'
20'
30'
40'
205
168
140
115
N/R
135
125
110
INSTALLATION
SHUT
60'
80'
100'
OFF (Ft.)
72
N/R
N/R
77
89
62
19
110
POWER
WEIGHT
CORD (ft.)
(lbs.)
20
85
20
85
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Little Giant 20E-CIM

  • Página 1 The E Series Effluent Pumps have 3/4" spherical solids handling capability. INSTALLATION Little Giant offers a complete line of float switches and liquid level control sys- tems for automatic operation along with a complete line of alarms, basins, cov- ers, and check valves.
  • Página 2: Cleaning Impeller And Volute

    LUBRICATED WITH DIELECTRIC OIL AND SEALED AT THE FACTORY. REMOVAL OF THESE SOCKET HEAD CAP SCREWS BY ANYONE OTHER THAN AN AUTHORIZED LITTLE GIANT SERVICE CENTER WILL BREAK THIS eter and 36" deep, and vented in accordance with local plumbing codes.
  • Página 3: Caractéristiques Techniques

    DESCRIPTION Afin de réduire le risque d’électrocution, faire preuve d’une grande prudence Les pompes submersibles à fosse septique à éjecteur Little Giant, série 20S, pendant le remplacement des fusibles. Ne pas avoir les pieds dans l’eau ainsi que les pompe à effluent de la série 20E sont recommandées dans le cas pendant le remplacement des fusibles et ne pas insérer le doigt dans les...
  • Página 4: Introducción

    Este alto nivel podría causar quemaduras de la piel si se toca la bomba y puede causar daños graves a la bomba. Little Giant oferta una línea completa de interruptores de flotantes y sistemas de control de nivel de líquido para el funcionamiento automático, conjuntamente con No engrase el motor.
  • Página 5: Mantenimiento

    DE CABEZA HUECA POR CUALQUIERA QUE NO SEA UN TECNICO DE UN cuando se están tratando cuerpos sólidos. No se instale la válvula en posición CENTRO DE SERVICIO LITTLE GIANT, ROMPERA ESTE SELLO E INVALIDARA vertical, pues los cuerpos sólidos pueden depositarse en ella y evitar la apertura LA GARANTIA.
  • Página 6 TROUBLESHOOTING INFORMATION • INFORMATION SUR LA RELÈVE DES DÉRANGEMENTS • INFORMACION DE INVESTIGACION DE AVERIAS PROBLEM • FONCTIONNEMENT DÉFECTEUX • PROBABLE CAUSES • CAUSES PROBABLES CORRECTIVE ACTION • SOLUTIONS PROBLEMA • CAUSAS PROBABLES • SOLUCION Pump not plugged in. • La pompe n’est pas branchée. • La bomba no Plug in pump.
  • Página 7: Warranty Period

    à la and/or affixing any LITTLE GIANT product, part or component thereof. seule discrétion de LITTLE GIANT, et ce en tout temps. Les dommages dûs à la foudre ou à des circonstances hors du contrôle de LITTLE GIANT NE SONT PAS THIS WARRANTY WILL NOT APPLY: COUVERTS PAR LA PRÉSENTE GARANTIE.
  • Página 8: Garantia Limitada Sumidero, Efluentes Y Aguas Residuales Residenciales

    Giant de las Series #6E, #8E, #9E, #10E, #14EH, #16EH, y #20E, en sumideros, a LITTLE GIANT en Oklahoma City, OK o a cualquier otro sitio que LITTLE GIANT depósitos, o estaciones de impulsión, y son adecuadas para bombear agua de pueda designar.

Este manual también es adecuado para:

20s-cimPump company 20e-cimPump company 20s-cim520100520200

Tabla de contenido