S U M O T U W E T H F R S A D A Y S
Tin,e & Day
Time & Day
Regen Tin,e & Day
Regen Time & Day
Salt
Salt
Capacity
Hardness
Capacity
Hardness
The controller will begin a manual regen, and advance the control valve to the cycle C1
(Backwash). Press the SET and UP button to advance to cycle C2 (Draw).
B. With the controller in this position, check to see that the water in the brine tank is
being drawn out of the tank. The water level in the tank should recede very slowly.
C. Observe the water being drawn from the brine tank for at least three minutes. If
the water level does not recede, or goes up, check all hose connections. C2 should be
displayed.
7. If the water level is receding from the brine tank you can then advance the control-
ler back to the treated water (C0) position by pressing SET and the UP buttons simul-
taneously to advance the controller to the C0 position.
8. Finally, turn on a faucet plumbed after the water conditioner. Run the faucet until the
water runs clear. Add salt to the brine tank.
17 • 8/08 AQU36WS
NOTE: We recommend that you do not put salt into the tank until
after the control valve has been put into operation. With no salt
in the tank, it is much easier to view water flow and motion in the
tank.
5. Engage the refill cycle to prime the line between the
regenerant tank and the valve (conditioner only).
A. Slowly open the main water supply valve again, to the
fully open position. Be sure not to open too rapidly as
that would push the media out of the media tank.
B. Advance the controller to the Refill (C8) position. From
cycle C1 (Backwash), press and hold the SET button.
This will display the current cycle.
While pressing the SET button, press UP to advance
to the next cycle. Continue to advance through each
cycle until you have reached cycle C8 (Refill).
NOTE: As you advance through each cycle there will be a slight
delay before you can advance to the next cycle. The hourglass icon
will light while the camshaft is indexing. There may be a pause at
cycle C4 (System Pause). This cycle allows the water/air pressure
to equalize on each side of the valve discs before moving on. The
hourglass will not be visible indicating that the system is paused.
C. With the water supply completely open, when you ar-
rive at cycle C8 (Refill), the controller will direct water
down through the line to the brine tank. Let the
water flow through the line until all air bubbles have
been purged from the line.
D. Do not let the water flow down the line to tank for more
than one minute to two minutes or tank may overfill.
E. Once the air is purged from the line, press the SET
button and the UP button simultaneously to advance
to cycle C0 (Treated Water) position.
6. Draw water from the brine tank.
A. From the treated water position (cycle C0), advance
the valve to the draw regenerant position. Hold the
REGEN button down for five seconds.