THings YoU MigHT need To knoW
• When the controller is first plugged in, it may display a flashing hourglass and the mes-
sage Err 3, this means that the controller is rotating to the home position. If the Err 2 is
displayed, check that the incoming power frequency matches the controller. The North
American controller will not run with 50 Hz input.
• The preset default time of regeneration is 2:00 AM.
• English or Metric? The World controller senses the electrical input and decides which is
needed. The North American controller only runs on 60 Hz and defaults to English units.
• The 700 Series controller can be programmed to regenerate on specific days of the week.
• The 700 Series controllers send commands to the motor for camshaft movement. How-
ever, water pressure/flow are required during the regeneration cycle for backwash, purge
and refill, and brine draw to actually take place.
• Plug transformer into a 110 VAC outlet that is NOT controlled by a wall switch.
19 • 8/08 AQU36WS