aQU36 ConTRolleR ·
1. Days of the week. The flag immediately below
the day will appear when that day has been
programmed as a day the system should
regenerate (used with 7-day timer programming).
2. See #3
3. This cursor is displayed when the days
between regeneration are being programmed
(used with .5 to 99 day regeneration
programming).
4. One of these cursors will be displayed to
indicate which day will be programmed into the
controller.
5. "PM" indicates that the time displayed is
between 12:00 noon and 12:00 midnight (there
is no AM indicator). PM indicator is not used if
clock mode is set to 24-hour.
6. When "MIN" is displayed, the value entered is
in minute increments.
7. When "Kg" is displayed, the value entered is in
kilograms or kilograins.
8. Four digits used to display the time or
program value. Also used for error codes.
9. Colon flashes as part of the time display.
Indicates normal operation.
10. Locked/unlocked indicator. In Level I
programming this is displayed when the current
parameter is locked-out. It is also used in Level
II programming to indicate if the displayed
parameter will be locked (icon will flash) when
controller is in Level I.
11. When "x2" is displayed, a second
regeneration has been called for.
12. The recycle sign is displayed (flashing) when
a regeneration at the next time of regeneration
has been called for. Also displayed (continuous)
21 • 8/08 AQU36WS
figURe 1
1
16
17
15
14
Time & Day
13
Regen Time & Day
12
11
25
24
23
10
9
SU
MO TU
WE
TH
FR
Salt
x2
C
Capacity
P
H
Hardness
22
20
19
21
when in regeneration.
13. The display cursor is next to "SALT" when
programming the amount of regenerant. If the
controller is on a 3-cycle filter then backwash
time is programmed.
14. The display cursor is next to "REGEN
TIME & DAY" when programming the time of
regeneration and the days of regeneration.
15. The display cursor is next to "TIME & DAY"
when programming the current time and day.
16. The hourglass is displayed when the motor is
running. The camshaft should be turning.
17. These cursors will appear next to the item
that is currently displayed.
18. X100 multiplier for large values.
19. Shows when water is flowing through the
valve.
20. Used with #24 and #25. Displays a
sequence number or a value.
21. History Values (H). The number displayed
by #23 identifies which history value is currently
displayed.
22. Parameter (P). Displayed only in Level II
Programming. The number displayed by #23
identifies which parameter is currently displayed.
23. Cycle(C). The number displayed by #23 is
the current cycle in the regeneration sequence.
24. Hardness setting—only used with 760 and
760C controllers.
25. Capacity display—shows estimated system
capacity.
2
3
SA DAYS
4
5
PM
MIN
LBS
6
KG
x100
7
18
Figure 1