PRobleM
Err1 is displayed
Err2 is displayed
Err3 is displayed
Four dashes
displayed.
— — : — — 1.
Brine tank
overflow.
2. Flowing or
dripping water at
drain or brine line
after regenera-
tion.
41 • 8/08 AQU36WS
PaUsible CaUse
Controller power has been connected
and the control is not sure of the state
of the operation.
Controller power does not match 50 or
60 Hz.
Controller does not know the position
of the camshaft. Camshaft should be
rotating to find Home position.
Camshaft is not turning during ERR 3
display.
If camshaft is turning for more than five
minutes to find Home position:
Power failure occurred. Uncontrolled
brine refill flow rate.
b. Air leak in brine line to air check.
c. Drain control clogged with resin
or other debris.
a. Valve stem return spring weak.
b. Debris is preventing valve disc
from closing.
solUTion
Press the UP arrow and the control
should reset.
Disconnect and reconnect the power.
If problem persists, obtain the
appropriate controller or AC adapter
for either 50 or 60 Hz power.
Wait for two minutes for the control-
ler to return to Home position. The
hourglass should be flashing on the
display indicating the motor is run-
ning.
Check that motor is connected.
Verify that motor wire harness is
connected to motor and controller
module. Verify that optical sensor is
connected and in place. Verify that
motor gear has engaged cam gear.
If everything is connected, try replac-
ing in this order:
—Wire harness
—Motor
—Optical sensor
—Controller
Verify that optical sensor is in place
and connected to wire. Verify that
camshaft is connected appropriately.
Verify that no dirt or rubbish is clog-
ging any of the cam slots. If motor
continues to rotate indefinitely,
replace the following components in
this order:
—Wire harness
—Motor
—Optical sensor
—Controller
Press SET to reset the time display.
a. Remove brine control to clean ball
and seat.
b. Check all connections in brine line
for leaks. Refer to instructions.
c. Clean drain control.
a. Replace spring. (Contact dealer.)
b. Remove debris.