Parameters; Parameters Configuration; Internal Counting (A/D); Configuration Of The Weight Limits (Superior And Inferior) - Baxtran BR 15 Manual De Instrucciones

Ocultar thumbs Ver también para BR 15:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.4 UNIT RANGE / MULTI-RANGE / MULTI-INTERVAL
The indicator can be configured with an only range, a maximum weight and a value of step. It can also be configured as multi range or multi
interval, in such cases there is a maximum weight.
From 0 to the medium weight of these maximum weight it is used the value of the chosen step ( step 1) and from the half to the maximum
weight it is used the next value in the step ( step 2).
The screen indicators R1 and R2 point out the range which the user is using at every moment.
In the multi interval mode the weight increases, in the range use it used step 1, when the user goes to range 2 the step 2 is used.
When the weight decreases and the user go back to range 1, the step 1 is used again. On the contrary, in mode multi range, when the weight
decreases and the device go back to range 1, the device continues using step 2 until it reaches 0.
In the section LF2 of the technical parameters the user can choose the range mode.

7. PARAMETERS

8. PARAMETERS CONFIGURATION

8.1

INTERNAL COUNTING (A/D)

8.2

CONFIGURATION OF THE WEIGHT LIMITS (SUPERIOR AND INFERIOR)

8.3

AUTO SWITCH OFF

8.4

CONFIGURATION OF THE ILLUMINATION OF THE DISPLAY

8.5

HOLD FUNCTION

8.6

RS-232 DATA EXIT

8.7

CONFIGURATION OF THE SPEED OF THE AD CONVERTER

8.8

BLIND

8.9

CONFIGURATION OF THE GRAVITY

To access the configuration of parameters when the screen is in zero, the user must press at the same time the keys
Press the key
or
To go back to the previous mode press the key
8.1 INTERNAL COUNTING (A/D) |
1. Press the key
2. To go to the next parameter, press the key
3. To exit this mode and go back to the normal weighing, the user must press the key
8.2 CONFIGURATION OF THE LIMITS OF WEIGHT ( SUPERIOR AND INGERIOR) |
1. Press the key
2. The display will show the message " 000.00L " ( inferior limit)
3. Use the keys
4. Press the key
PARAMETER
DESCRIPTION
Internal calculation (A/D)
UF-1
Limit Configuration of weight ( superior and inferior)
UF-2
auto auto off
UF-3
Back illumination of display
UF-4
Four modes of hold
UF-5
RS-232 Output ( PC/PRINT)
UF-6
Configuration of the speed of the converter (A/D)
UF-7
blind
UF-8
Configuration of gravity
UF-9
to choose the desired character (UF-1 ~ UF-11 ).
UF-1
to view the internal sums of the scale.
the screen will show the value of the voltage of the battery.
to access the parameter.
and
to move the cursor and the key
to confirm.
.
to choose the desired number..
USER'S MANUAL BR15
or
UF-2
EN
and
.
39

Publicidad

Tabla de contenido
loading