E
Post gas.
10.0s
Adjustable from 0 to +10 seconds.
F
Menu.
MENU
To enter this function select it with your finger.
Selecting it you enter the Main Menu.
SELECTION OF THE WELDING
Process
CESS, MIG, TIG or MMA (see explanation
under chapter MIG Process).
Parameters SELECTION OF PROCESS PARAMETERS
(see explanation under paragraph Start
Mode mode 3L of chapter MIG Process).
Accessories USE OF MACHINE ACCESSORIES (see ex-
planation under chapter MIG Process).
Settings MACHINE SETTINGS MENU (see explana-
tion under chapter MIG Process).
G
Job Menu (see explanation under chap-
JOB
ter MIG Process).
6.3 MMA PROCESS.
O
A
A
The screen displays the welding current in Amperes
and the welding voltage in Volts.
M L
I
H
B
C
F
B
Hot Start.
It is the overvoltage supplied at the arc ignition time.
It is adjustable from 0 to 100% of set welding current.
C
Arc Force.
It is the adjustment of the arc dynamic chara teristic.It is
adjustable from 0 to 100% of set welding current.
F
Menu.
MENU
To enter this function select it with your finger.
Selecting it you enter the Main Menu.
PRO-
SELECTION OF THE WELDING
Process
CESS, MIG, TIG or MMA (see explanation
under chapter MIG Process).
Parameters PROCESS PARAMETERS SELECTION.
• Hot Start.
It is the time of overvoltage supplied at the arc ignition
time.
Range from 0 to 100 sec.
Turn the knob 2 to select the parameter and confirm
the selection by pressing the knob.
To adjust the value simply turn the knob 2. To confirm
the selection press knob 2 or the key
Press the key DEF to reset the factory set parameters.
N
• Hot Start Time.
It is the time of overvoltage supplied at the arc ignition
time.
Range from 0 to 100 sec.
G
Turn the knob 2 to select the parameter and confirm
the selection by pressing the knob.
To adjust the value simply turn the knob 2. To confirm
the selection press knob 2 or the key
Press the key DEF to reset the factory set parameters.
PRO-
.
.
27