7. PARAMeTeRs
8. PARAmETERS CONFIgURATION
to access the configuration of parameters when the screen is in zero, the user must press at the same time the keys
Press the key
or
to go back to the previous mode press the key
8.1 INTErNAL COuNTING (A/d) | uF-1
1. Press the key
to view the internal sums of the scale.
2. the display DISPLAY WEIgHt
3. the display DISPLAY AVERAgE PIECE WEIgHt
4. the display PIECES will show the value counting internal of zero.
3. to exit this mode and go back to the normal weighing, the user must press the key
8.2 CONFIGurATION AVErAGE wEIGhT OF uNIT| uF-2
1. Press the key
to access the parameter.
2. the display will show the message "
Numerical keyboard
3. Use the keys
number:
AAvG 0
= desactivated
AAvG 1
= activated (factory default)
this function is specially designed for counting pieces, reducing and
minimizing the error, obtaining this way some proved more precise.
8.3 AuTO SwITCh OFF| uF-3
MODES:
•
AoFF 00
– Auto switch off deactivated. (factory default)
•
AoFF 01
– Auto switch off activated in a minute. the scale is going to switch off automatically after 1 minute of not being used.
•
You can configure the value wished from 1 to 99 minutes.
1. Press the Key
2. Use the
NUMERICAL KEYBOARDS
3. Press the Key
8.4 dISPLAy BACkLIGhTING | uF-4
MODES:
(factory default)
•
LIT 0:
Automatic
•
LIT 1
: Illumination Activated.
•
LIT 2
:Illumination Deactivated.
PARAmETERS
DESCRIPTION
Internal calculation (A/D) and battery voltage
UF-1
Autoaverage unit weight
UF-2
auto auto off
UF-3
Back illumination of display
UF-4
accumulation
UF-5
Output RS-232(PC / PRINt) (not function on tC15)
UF-6
Configuration of the speed of the converter (A/D)
UF-7
Initial zero
UF-8
to choose the desired character (Uf-1 ~ Uf-8)
.
will show internal countings fS.
AAvG1
"
to select the desired
to have an access to the parameter
to select the desired number.
to confirm or press the Key
.
will show the value of battery voltage.
Note:
When the function Uf-2 is activated the piece counting function is
realized normally. If you add another weight which has less than
twice the first sample weight, the indicator will recalculate automati-
cally the unit weight, so that the result will be more accurate.
Example:
We have 10 pieces with a total weight of 13.7 g, the value of the unit
weight will be of 1,37292g/pcs. Immediately afterwards we add 13
pieces with a total weight of 18.4 g, that is lower than the double of
13.7g (27.4g). the scale will count 23 pieces and will update the
value of the unitary weight automatically, changing to 1,39384g/
pcs.
to return to
UF-3
USER'S MANUAL TC15
or
eN
and
.
27