Kohler K-1418 Guia Del Usuario página 14

Ocultar thumbs Ver también para K-1418:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Troubleshooting the Neckjet System
Symptoms
14. Keypad does not
respond when
neckjet mode is
selected.
15. Pump operates but
neckjets do not turn
j
on. Indicator bar on
on Indicato ba on
user keypad is
flashing.
flashing.
16. Pump operates but
neckjets do not turn
j
on. Indicator bar on
on Indicato ba on
user keypad is NOT
flashing.
17. Water flows from
neckjets, but
neckjets do not
j
pulse.
l
A
1023249-5-
Probable Causes
A. Faulty user keypad.
A. Pillow is not installed.
B. Reed switch is faulty.
C. Wiring harness from neckjet to control
is loose, disconnected or damaged.
A. Neckjet line is blocked.
B. Wiring harness from neckjet to control
is loose, disconnected or damaged.
C. Faulty butterfly valve.
D. Faulty control.
A. Wiring harness from neckjet pulse
canister to control is loose,
disconnected or damaged.
B. Faulty pulse canister.
C. Faulty control.
Recommended Action
A. Replace user keypad. Refer to
installer/dealer.
A. Make sure the pillow is properly
attached to the neckjet body.
B. Check reed switch wiring and replace if
necessary. Refer to installer/dealer.
C. Check wiring for proper connections.
Replace wiring harness if necessary.
Refer to installer/dealer.
A. Disconnect neckjet hoses and remove
blockage.
B. Check wiring for proper connections.
Replace wiring harness if necessary.
Refer to installer/dealer.
C. Replace butterfly valve. Refer to
installer/dealer.
D. Replace control. Refer to installer/dealer.
A. Check wiring for proper connections.
Replace wiring harness if necessary.
Refer to installer/dealer.
B. Replace pulse canister. Refer to
installer/dealer.
C. Replace control. Refer to installer/dealer.
14
Kohler Co.

Publicidad

Tabla de contenido
loading

Tabla de contenido