Troubleshooting
PROBLEM
EO is displayed on
LED Screen.
E1 is displayed on
LED Screen.
E2 is displayed on
LED Screen.
E3 is displayed on LED
Screen, Beeping
The appliance automatically
switches to Keep Warm
without going through a
complete cooking cycle.
Air is escaping from
the rim of the lid.
Steam is released from
the safety locking pin
during cooking.
EASY SOLUTION
•
Check that lid is closed properly.
•
Check that the Pressure Release Valve is in the correct position.
•
Make sure the silicone rubber gasket is in good condition and attached
properly to the gasket holder.
•
Unplug unit and allow to sit for 20 minutes. If no change, Please call
Breville Consumer Support.
•
Ensure the cooking bowl is properly positioned inside base.
The cooking bowl must be in direct contact with the heating plate.
Make sure there are no unwanted materials on the heating plate.
•
SAUTE/SEAR setting will not work if the lid is on or locked in position.
Ensure the lid is off or placed on top of the appliance in an offset position.
•
Add more water to cooking bowl and restart the cooking cycle.
•
Make sure the silicone rubber sealing gasket is in good condition and
attached properly to the gasket holder .
•
Check that lid is closed properly.
•
Inspect the safety locking pin (see page 9, letter "U"). The pin should
move up and down freely, and have a silicone seal on one end.
Clean the pin and replace the seal if necessary.
•
Make sure the silicone rubber sealing gasket is in good condition and
attached properly to the gasket holder.
29