3.6
Residual risks
Danger due to moving
mechanical components
Danger due to edges and
angles
Danger due to electric
hazard
Danger due to thermal
hazard
3.7

Prohibitions

In particular, employees must not:
- mount on the pump to prevent falls;
- remove or modify without authorization any security device, security signal or security control ;
- perform operations on their own initiative that could compromise the safety of themselves or other operators;
- wear bracelets, rings and necklaces that can be hanged or dragged by moving parts, creating danger conditions;
- use the machinery if there is any malfunctioning;
- apply any precarious repairs.
3.8

Noise level

The acustic pressure levels of the products, properly installed and functioning within the use limits foreseen in the relative technical catalog does
not reach 70 dB(A).
3.9

Unintended and/or improper uses

Do not use the machine in the following conditions:
- waterless;
- without the protection grids properly installed;
- exceeding the limits specified on the identification plate;
- for pumping different liquids from those specified in the relative catalog.
Do not use the machine for different purposes than those specified in the relative product catalog. Any different use from those
specified in the relative product catalog is to be considered improper and therefore potentially dangerous to the safety of workers,
as well as to invalidate the contractual warranty.
3.10

Warranty

Warranty of the products are subject to ROVATTI A. & FIGLI POMPE S.p.A. general sale conditions. For more information about Rovatti
terms and conditions, plase visit "www.rovatti.it". Warranty is recognized when all mechanical, hydraulic, electric norms and correct use indi-
cated on the present manual are respected.
16
MGES4205R2
Hazard of getting caught and drawn into machine pinch points by loose clothing that
become entangled. Pinch points are represented by all rotating or revolving parts
and by power transmission apparatus. Follow lockout procedure before servicing. Do
not operate without proper protective guards. Stay clear of the machine area while
operating
Whenever possible we have provided for corner guards and eliminated protruding
parts. Use proper protective guards, like gloves, eye-glasses etc. during maintenance
and cleaning operations
The terminal block connecting the electric network to general panel remains live also
when in stand-by for servicing operation. Before making any connection or mainte-
nance on these parts disconnect electric power from network supply cable to the ma-
chine. We recommend to mount a disconnecting switch upstream in order to insulate
the power supply, to ensure safety maintenance operations
Thermal hazards on this type of machine are concentrated determinated areas. While
operating the temperature of these areas can reach and exceed 50°C. Avoid any
direct contact with these components. Wait for complete cooling oin order to prevent
burns