3
Technical data
3.1
General data and operating conditions
Conformity and approval
Conformity
CE
Approval
In preparation: UL
Supply system data
Supply forms
Noise emission
Noise immunity (according to requirements of EN 61800-3)
Electrostatic discharge
(ESD)
Radio frequency
Conducted
Radiation (housing)
Protection of persons and equipment
Enclosure
Insulation resistance
Insulation of control
circuits
Short-circuit strength
Leakage current
Cyclic mains switching
Design
Housing
Carrier housing
Carrier housing
Dimensions
Weight
EDK94PNE245 DE/EN/FR/ES/IT 1.0
General data and operating conditions
73/23/EEC
Low-Voltage Directive
UL 508C
Industrial Control Equipment, file no. 132659
With earthed
Unrestricted use
point
IT systems
Observe instructions about special measures!
EN 61800-3
Conducted: cannot be specified because dependent on the
conditions present in the interconnected system
Radiation: category C3
EN 61000-4-2
8 kV for air discharge,
4 kV for contact discharge to housing
EN 61000-4-6
150 kHz ... 80 MHz, 10 V/m 80 % AM (1 kHz)
EN 61000-4-3
80 MHz ... 1000 MHz, 10 V/m 80 % AM (1 kHz)
EN 60529
IP 20
NEMA 250
Protection against contact to
type 1
EN 61800-5-1
Overvoltage category III
Derating at and above 2000 m amsl: overvoltage category II
EN 61800-5-1
Safe mains isolation by double/reinforced insulation.
EN 61800-5-1
DC-bus connection: not short-circuit-proof
Brake resistor connection: fully short-circuit proof
Control connections: fully short-circuit proof
EN 61800-5-1
> 3.5 mA
Cyclic mains switching of 5 times within 5 minutes is
permitted without restrictions.
Device sizes
Glass-fiber reinforced plastic
I and III
Device sizes
Metal
4 and 5
See "Mechanical installation"
See "Mechanical installation"
Technical data
Not in the wiring area of
the lower terminals
Observe regulations and
safety instructions!
3
39