Flange
Stud Wall
Ledger Strip
18-3/4"
(476 mm) 3/16"
(5 mm)
Subfloor
8-3/4" (222 mm) for series 7726, 7727 and 7728
11-3/4" (298 mm) for series 7730 and 7731
10. Secure the Bath – Alcove
Refer to the "Roughing-In" section for recommended clip locations.
Verify the studs are within 1/8" (3 mm) of the bath at the recommended support clip locations.
Shim if necessary.
Slide the bottom of each attachment clip into the space between the bath flange and stud until the
tab touches the bath.
Secure the attachment clips with galvanized or plated flathead screws.
Sterling
Attachment Clip
Ø 2-1/2" (64 mm) Overflow
17" (432 mm)
Ø 2" (51 mm)
Overflow Height
Drain
5-1/4" (133 mm) for series 7726, 7727 and 7728
5-15/16" (151 mm) for series 7730 and 7731
15
Attachment Clip
Tab
1139487-2-F