2.3
Victrix 24 kW - Control panel.
Key to control panel display symbols
Description
Figures to indicate temperature, any error codes or
Optional external temperature sensor correlation
factor
Degrees symbol
External sensor connection symbol
(Optional)
Symbol for connection to Remote Friend Control
device
Summer symbol (domestic hot water production
only)
Winter symbol (domestic hot water production
and room heating)
Domestic hot water production phase on symbol
Room heating phase on symbol
Flue cleaning function symbol
Malfunction symbol (combined with error code)
Flame present symbol
Burner output scale symbol
2.4
Boiler lighting.
Before lighting, make sure that the system is full of water checking that the
manometer (5) indicates a pressure of 1÷1.2 bar.
- Open the gas valve upstream of the boiler.
- Turn the main selector (2) to Domestic/Remote Friend Control (
or Domestic and Heating (
Symbol
).
Key:
• Operation with Remote Friend Control (Optional). With the selector
(2) set to (
) and Remote Friend Control connected the boiler
selectors (3) and (4) are cut out; the display shows the symbol (
The boiler adjustment parameters are set from the control panel of the
Remote Friend Control.
• Operation without Remote Friend Control. With the selector (2) set
to (
) the heating adjustment selector (4) is cut out, the domestic
hot water temperature is regulated by selector (3); the display shows the
Summer symbol (
adjustment selector (4) is used to regulate the temperature of radiators,
while selector (3) continues to be used for domestic hot water; the display
shows the Winter symbol (
Turn the selectors clockwise to increase the temperature, and anticlock-
wise to lower the temperature. During regulation, the temperature being
set appears momentarily on the display
production).
Boiler operation is now automatic. With no demand for heat (heating or
domestic hot water production) the boilder goes to "standby" function,
equivalent to the boiler being fed without presence of flame, in this condition
only the boiler setup symbol (Summer or Winter and possibly connection
to RFC) appears on the display. Each time the boiler lights up, the relative
flame present symbol, the power delivered by the burner and the delivery
temperature are shown on the display, combined with the symbol for the
type of operation requested: (
) for room heating.
)
1 - Boiler status indicator display
2 - Stand-by - Domestic/Remote control -
Domestic and Heating - Reset Selector
3 - Domestic hot water temperature selector
4 - Heating temperature selector
5 - Boiler manometer
). With the selector set to (
).
(heating or domestic hot water
) for domestic hot water heating and (
ES
PL
TR
CZ
SI
HU
RU
).
IE
SK
) the heating
195