Festo P.BE−K−CMMS−AS 0708NH English
Error message
Error message
Fault in reference
travel
CAN communica
tion fault
Initialization fault
Drag error
Motor/controller
temperature 5 °C
below maximum
2
I
t at 80 %
Fault in offset cur
rent measurement
Fault in PROFIBUS
Checksum fault
SD card
2
I
t−fault
Time out with fast
stop
Cause/Measures
Cause/Measures
Reference travel
interrupted
Signal faults or internal
fault
Internal fault
Enlarge fault window,
reduce acceleration
Check application
Check application
Internal fault
Slave address, bus
termination and cabling.
Internal fault
Internal fault
Card does not exist,
full or defective
Mechanical part
blocked, check
application