FinishPro II 395 Error Codes

Display
No Display
Sprayer stops. Power is not applied. Sprayer
may be pressurized.
3000 psi
Sprayer is pressurized. Power is applied.
210 bar
(Pressure varies with tip size and pressure
21 MPa
control setting.)
E=02
Sprayer may continue to run. Power is applied.
E=03
Sprayer stops. Power is applied.
E=04
Sprayer stops. Power is applied.
E=05
Sprayer does not start or stops. Power is
applied.
- - - -
Power is applied.
EMPTY
Sprayer stops. Power is applied.
333120A
Sprayer Operation
Indicates
Loss of power.
Check power source. Relieve
pressure before repair or
disassembly.
Normal operation.
Spray.
Pressure greater than
Replace pressure control board
4500 psi (310 bar,
or pressure transducer.
31 mpa) or a pressure
transducer is faulty.
Pressure transducer
Check transducer connection.
faulty, bad connection
Open drain valve. Substitute
or broken wire.
new transducer for transducer
in sprayer. If sprayer runs,
replace transducer.
Line voltage too high.
Check for voltage supply
problem.
Motor fault.
Check for locked rotor, shorted
wiring or disconnected motor.
Repair or replace failed parts.
Pressure is less than
Increase pressure if desired.
200 psi (14 bar, 1.4 MPa).
Drain valve may be open.
Empty paint pail. Loss of
Refill paint pail. Check for leaks
pressure.
or clogged pump inlet. Repeat
Startup procedure.