The machine must be installed and commissioned in complete compliance with safety regulations, p rocedures and
standing laws. The installation technician bears the responsibility of ensuring compliance with fire safety requirements;
seek all necessary advice from the local fire-fighting authorities. Position the machine in the allocated site. Adjust the
machine feet until the appliance is perfectly level. In the case of particularly heavy equipment, use appropriate lifting
means. If the appliance is not perfectly level, correct operation and condensate flow-off will not be assured.
AVOID:
AMBIENT TEMPERATURE AND AIR CIRCULATION:
For air-cooled appliances, the maximum ambient temperature for operation is 32°c. Correct operation cannot be
guaranteed at higher temperatures. The machine may operate safely to a maximum temperature of 38°c. Remote
condensing units must be installed in special rooms or outdoors, protected against direct sunlight by a shelter or roof
structure (at the cost of the purchaser). Sufficient air circulation must be guaranteed at all times.
CONDENSATE DRAINAGE CONNECTION
Fit a condensate/wash water drainage hose as picture or use water box tray under the refrigerator.