OPERATIONAL INSTRUCTION
POWER INSTRUCTIONS
The treadmill must be grounded. If the unit malfunctions or breaks, grounding
provides a path of least resistance to electric current, which reduces the risk of electric
shock. The unit comes equipped with a suitable power cord with a grounding wire for
the equipment and a plug with a ground pin. Only bipolar-type plugs with ground
(2P + T 20A in accordance with NBR 14136) will be accepted.
contact
acceptable to use any type of adapter for outlets without a ground pin. Outlets must
always be installed in appropriate boxes which do not allow their poles (of the outlet) to
be exposed. All outlets must be connected to the grounding pin. It is totally
unacceptable to use the neutral wire (when included in the installation) short-circuited
to the ground wire.
ATTENTION!
Improper connection of the equipment grounding wire may result in a risk
of electric shock. Consult a qualified professional or maintenance personnel
if you do not know if the unit is properly grounded. Do not replace the
original treadmill plug.
If it does not fit the outlet, obtain a suitable outlet installed by a qualified
electrician.
CAUTION!
According to NBR 5410, a thermomagnetic protection circuit breaker with
the following characteristics must be provided at the specific outlet where
the equipment will be connected:
•Circuit breaker: 25 Amperes - ACTIVATION CURVE B - For 220v networks.
•Circuit Breaker: 32 Amperes - ACTIVATION CURVE B - For 220v networks for
3hp motor
The circuit breaker has the function of protecting the equipment in case of
an electrical breakdown that causes a dangerous increase in the electric
current.
NOTE: THE BREAKER INSTALLATION MUST BE IN ACCORDANCE WITH THE
NBR 5410 STANDARD, WHICH IS MANDATORY FOR LOW VOLTAGE
F
Ø4,8 mm
33
It is not
T
N
20 A
Orifice