AVENTICS | Bus Coupler AES/Valve Driver AV, EtherNet/IP | R412018139–BAL–001–AF
12.3.5
Rating plate on bus coupler
The rating plate is located on the back of the bus coupler. It contains the following information:
47
48
49
50
51
52
53
54
55
Fig. 15: Bus coupler rating plate
47 Logo
48 Series
49 Mat. no.
50 MAC address
51 Power supply
52 Manufacture date (FD) with format "FD:
<YY>W<WW>"
12.4 PLC configuration key
12.4.1
PLC configuration key for the valve zone
The PLC configuration key for the valve zone (59) is printed on the right end plate.
The PLC configuration key specifies the sequence and type of electrical components based on a
numerical/alphabetical code. The PLC configuration key consists solely of numbers, letters,
and dashes. There are no spaces between the values.
In general:
Numbers and letters refer to the electrical components.
Each digit corresponds to one valve driver board. The number's value refers to the number of
valve positions for a valve driver board.
59
Letters refer to special modules that are relevant to the PLC configuration.
"–" visualizes a pneumatic supply plate without UA-OFF monitoring board; not relevant to the
PLC configuration
The sequence begins on the right side of the bus coupler and ends at the right end of the valve
system.
The elements that can be represented in a PLC configuration key are shown in Table 26.
Conversion of the Valve System
58
57
53 Serial number
55 Country of manufacture
56 Data Matrix code
57 CE mark
58 Internal plant ID
111